Class 2 Biosafety Cabinets are designed to provide protection to operator, environment and materials inside the workspace. These Class II BSCs are utilized for containing low-to-moderate risk biohazardous materials. These cabinets have downward airflow and HEPA filters that re-circulate air providing required level of protection from microorganisms and aerosols. these cabinets are extensively used in drug preparation, chemotherapy preparation, clinical research, medical and pharmaceutical sectors, life science and industrial laboratories etc. it must follow relevant application specific standards.
A Biosafety cabinet known by several names in research industry; microbiological safety cabinet, biological safety cabinet (Acronym: BSC) and Biosafety hood are such common names which are referred by microbiologists.
In order to meet varying research and clinical needs, Class II Biosafety Cabinets are designed mostly in 3 types i.e. Type A2, Type B1, and Type B2. Regardless of type, each cabinet provides the same level of protection. According to international sanitation standards, there are exactly same pass and fail criteria for all of them.
Now how do we differentiate each Class 2 Biosafety Cabinet? Each cabinet is differentiated by a number of factors some of them are amount of air re-circulation, air ventilation and negative and positive pressure. Before buying a cabinet a user must know the basic differences between these 3 types of Biosafety cabinets which are explains below:
this type of Class II BSC, approximately 70% of the HEPA filtered air circulated through the cabinet, while 30% passes through an exhaust HEPA filter and is discharged.
This Class II BSC, exhausts 60% – 70% of the HEPA filtered air, while 30% – 40% air re-circulated inside workspace through HEPA filter.
It is total exhaust type BSC, no re-circulation inside workspace; blower exhausts 100% of the filtered air.
In order to take optimum use of a Biosafety cabinet and maintain operational integrity, proper maintenance is essential. A Biosafety operator must follow routine cleaning and inspection schedule. chemicals extensively used in BSC cabinets, filter saturation should be checked regularly, if need replace it immediately. Other minor check-ups must be done on regular basis such as air flow, surface cleaning, motor, and lighting and electrical switches etc.
SUNIL BROTHERS is India’s leading Biosafety cabinet company, which manufactures and supplies most reliable, durable and energy efficient Biosafety cabinets following European Standard EN12469 and NSF Standards. These cabinets provide higher level of protection to operator, environment and samples. Our Class 2 Biosafety Cabinets are available in 4 different sizes (3ft, 4ft, 5ft and 6 ft), designed as ducted or recirculating type and offer unique safety features. There are various design options and accessories available in order to make a cabinet adaptable to almost every application. Each cabinet factory tested and delivers full value of your money, while remaining reasonable in price.
Class 5 conditions (class 100) per ISO 14644-1 and 2 | Hand rest for comfortable working |
Produces less heat and energy efficient | Highly efficient airflow management system |
Lightening through fluorescent lamp | Filters can be changed easily front side |
Durable construction for long service life | Durable wall plenum design |
Easy to clean and maintain | Powder coated MS exterior |
Low noise operation | Audio / visual sash alarm |
Nominal Size | 2 ft. | 3 ft. | 4 ft. | 5 ft. | 6 ft. |
Working area (ft.) | 2 x 2 x 2 | 3 x 2 x 2 | 4 x 2 x 2 | 5 x 2 x 2 | 6 x 2 x 2 |
Inflow Velocity | 105 fpm (.53 m/s) |
Downflow Velocity | 60 fpm (0.30 m/s) |
Noise Level | <65 dba |
Filter | HEPA filter 99.999% efficient (ULPA – Optional) |
Particle retention | 0.3 microns |
Light | Fluorescent light |
Light Intensity | 90 – 120 foot-candles |
Controller | Microprocessor controller w/ digital display |
Body Construction | Wooden / PCRC Sheet / SS 202 /SS 304 / SS 316 |
Table Construction | Stainless Steel 304 |
Front Door | Frameless auto sliding glass door OPTIONAL |
Pressure Gauge | Static pressure manometer (Magnehelic gauge optional) |
Blower assembly | 1/3 HP, Single Phase, 1440 RPM motor, Capacity 1000 CFM, Pressure 30 mm WG |
Exhaust assembly | 300 CFM, ducting by PVC pipe with rain guard – Dia. 150mm |
Certifications | NSF/ANSI 49 (Optional) |
Optional | -Raised airflow grill -Spare UV lamp -VacuumTap – Exhaust (LH / RH / Top) – Canopy exhaust connection (CEC) – Stand with rolling caster – IQ / OQ certifications |
Note | Please note specifications are subject to change. Please contact sunil brothers to verify before purchase. |
Sending...
DR LATA SHARDA
UPDATING AFTER 2 MONTH OF USING SB-BS4B-B2 MODEL . NICE FINISH . WORKING QUALITY IS SUPERB . VALUE FOR MONEY . PASSED BY NABH.
PLANING TO PURCHASE AGAIN SOON
DR TUSHAR
SATISFIED WITH THE QUALITY . EASY TO OPERATE . DELIVERED BEFORE PROMISED DATE .
RECENTLY WE HAVE GET IT NABL CERTIFICATE FOR THE SAME . FULLY SATISFIED WITH THE MACHINE .
USAID DISCOVER HEALTH zambia south africa
ULTIMATE WORKING QUALITY . NICE FINISH . FULLY SATISFIED WITH BOTH BIO-SAFETY CABINET